CND.OSTAR

PREVENTION

is always better than treatment

OSTAR HK-809 heart spectrum blood pressure monitor

  • shows accurate blood pressure measurement results by using the patented automatic correction and calibration technology


  • shows indexes of the health status of the heart by using the patented OSTAR heart spectrum technology


  • automatic self-examination and calibration of the OSTAR heart spectrum blood pressuremonitor upon switching on


  • shows the statistic and analysis report of the measurement data stored in the smartphone for daily, weekly, monthly or the slected period by using the exclusive application for OSTAR heart spectrum blood pressure measurement

Guaranteed accuracy


Provide highly reliable blood pressure readings with patented automatic correction and calibration technology


More information of the health of your heart


In addition to blood pressure and pulse values, also shows the health of your heart as the analysis results of your blood pressure measurement data by using the patented OSTAR heart spectrum technology


User self-defined blood pressure control settings


Provides customized settings for personal control values for blood pressure and heart rate in the OSTAR heart spectrum blood pressure monitor


Free measuremnt application for Android smartphone


The OSTAR heart spectrum blood pressure measurement application (Android-App) can be downloaded for free from the Google Play Store

Why can the OSTAR heart spectrum blood pressure monitor guarantee the accuracy of every measurement?

OSTAR has applied an innovative automatic correction and calibration technology in its heart spectrum blood pressure monitor to response to the environmental factors which are affecting the accuracy of the measurement.


There are many natural factors that affect the accuracy of a blood pressure monitor, such as ambient temperature, atmospheric pressure, height and latitud. In addition, after a certain period of use, the influence of the compenents quality and components aging problem should not be neglected.


Every time the OSTAR heart spectrum blood pressure monitor is turned on, the equipment performs an internal check of the measurement accuracy depending on its component status and environmental conditions such as temperature, humidity, barometric pressure, altitude, etc. Once the self-examination process detects a difference outside the tolerance of the built-in standard, the equipment will automatically correct and calibrate the equipment to restore the built-in measurement accuracy.

Why can the OSTAR heart spectrum blood pressure monitor show the healthy status of your heart?

OSTAR has applied the innovative heart spectrum technology, an analysis technology for blood pressure measurement data, into its heart spectrum blood pressure monitor to provide reference health information of the heart.


Upon completion of each blood pressure measurement, the OSTAR heart spectrum blood pressure monitor analyses the data collected during the measurement and displays numerical indices from 1 to a maximum of 20 if abnormal heart noises were detected during the analysis (which are heart arrhythmias, noises of heart valves and noises of coronary arteries).


  • The information showed by OSTAR heart spectrum blood pressure monitor are not medical diagnosis. Please always consult your doctor if you any questions about the reasults showed.


  • If you are taking any prescribed medication, please consult your doctor before using the equipment.

The Innovations

The unique

heart spectrum technology


The heart spectrum technolgy is a patented analysis technology developed by OSTAR Meditech Corp., Taiwan, by analyse the data collected on a blood pressure measurement to provide information about the healthy status of the heart. The results of the analysis are presented by three useful indexes that give an overview of the healthy status of your heart each time you measure your blood pressure.

Show you much more

not just arrhythmia


The OSTAR heart spectrum blood pressure monitor is a unique meaurement equipment on the market that displays much more information than just an indication of irregular heartbeat (arrhythmia).


The OSTAR heart spectrum blood pressure monitor will collect the measurement data throughout the measurement process. After completing the measurement, the CPU inside the OSTAR heart spectrum blood pressure monitor will use the heart spectrum technology to transmit the measurement data and to further analyse the data to find out if there are any abnormal frequencies (heart noises) discovered in the measurement period.


Using the heart spectrum technology, the OSTAR heart spectrum blood pressure monitor is able to identify heart noises caused by irregular heartbeats, not completely closed or prolapsed heart valves or abnormal vibrations of blood flow in the coronary artery.


The patented technology of OSTAR provides useful references for personal health management at home and helps you to take precautionary actions for the early diagnose potential heart diseases.

The unique

automatic correction and calibration technology


Each time the OSTAR heart spectrum blood pressure monitor is turned on it performs an internal check of the measurement accurancy according to the surrounding enviromental conditions such as temperature, humidity, air pressure, height , latitude, etc. and its components status. If any difference outside the tolerance of the built-in setting is found, the OSTAR heart spectrum blood pressure monitor will conduct an correction accordingly and calibrates the equipment to re-establish the measurement accuracy.

The individual settings of personal control target for 

blood pressure and pulse


Although the blood pressure readings 120mmHg/80mmHg are recognised as the optimal blood pressure readings, but due to difference in age, health situation and physical conditions, each person would have different ideal blood pressure readings to maintain.

 

With the settings of the alarm range of the OSTAR heart spectrum blood pressure monitor, once any measured reading of your blood pressure or your pulse exceed the control target your set, the reading will be displayed in flashing mode, so that you see the warning instantly.

The automatic

re-inflation function


When using the OSTAR HK-809 heart spectrum blood pressure monitor for blood pressure measurement, the equipment will first inflate the cuff until the preset maximum pressure (around 180 mmHg) is reached. Then the equipment will start to slowly deflate the cuff. During the deflating, the OSTAR HK-809 heart spectrum blood pressure monitor will measure the systolic blood pressure and the diastolic blood pressure.


If for any reason the correct blood pressure values can't be obtained during the deflating, the OSTAR HK-809 heart spectrum blood pressure monitor will automatically inflate the cuff again to a higher pressure (around 200 mmHg), then deflate the cuff again to complete the measurement.


With this function, the OSTAR blood pressure monitor can always obtain the correct readings of the blood pressure from the measurement.

Specifications

Measurement method

  • Electronic oscillometric method


Memory capacity

  • 30 sets measurement results, can be displayed in sequence
  • If new measurement is made after the memory is full, the oldest set of measurement results will be deleted automatically, so that the new measurement results can be saved


Display screen

  • LCD display screen
  • Displaying measurement results SYS/DIA/PUL and heart spectrum index I1/I2/I3 in sequence, with the date and time of the measurement


Pressurisation method for cuff

  • Automatic pressurisation


Range of the blood pressure measurement

  • 30 – 240 mmHg, scale: 1 mmHg
  • Accuracy: ±3 mmHg or 2% of the measured value


Range of the pulse measurement

  • 30 – 160 beats per minute, scale: 1 best per munite
  • Accuracy: ±2 beats per minute or 2% of the measured value


Power supply

  • Four (4) LR6 AA 1,5V alkaline batteries


Working environment

  • Temperaturr between 10 – 40 degree centigrade
  • Relative humidity between 30 – 85 %


Storage environment

  • Temperature between –20 – 60 degree centigrade
  • Relative humidity between 10 – 95 %


Dimension

  • Länge 145 mm, Breite 125 mm, Höhe 60 mm


Weight (exclusive batteries)

  • Equipment 410 g (± 10 g), coff 130 g (± 10 g)

How does it work?

Use of the

OSTAR heart spectrum technology


The heart spectrum technolgy is a patented analysis technology developed by OSTAR Meditech Corp., Taiwan, by analyse the data collected from a blood pressure measurement to provide information about the healthy status of the heart.


After the measurement, the collected measurement data is transformed into a frequency domain wave by means of FFT (fast Fourier Transformation). The frequency domain wave shows the main peak frequency. Clinical trials find that the main frequency peaks of the tranformed normal blood pressure measurement data is displayed with three identifiable regions. When a different peak frequency is identified from the main peak frequency, this abnormal peak frequency will be defined as heart noise and will be quantised as the heart spectrum index.


The sum of heart noise in the first frequency region is the value of the heart spectrum index I1 , and the sum of heart noise in the second frequency region is the value of the heart spectrum index I2, and the sum of heart noise in the third frequency region is the value of the heart spectrum index I3.


Clinical trials also indicate that the heart spectrum index I1 is the noise index of arrhythmia, and the heart spectrum index I2 is the noise index of the heart valve, und the heart spectrum index I3 is the noise index of the coronary artery.

With the unique innovative

automatic correction and calibration technology


ensures that the OSTAR heart spectrum blood pressure monitor shows the same reliable accurate measurement data in every mensurement.


After each measurement, the OSTAR heart spectrum blood pressure monitor displays two groups of measurement data:


Readings

  • Systolic blood pressure
  • Diastolic blood pressure
  • Pulse

Analysis resutls

  • Hear spectrum index I1
  • Hear spectrum index I2
  • Hear spectrum index I3


Range and accuracy of the blood pressure measurement

  • 30 – 240 mmHg, scale: 1 mmHg
  • accuracy: ±3 mmHg oder 2% of the measured values


Range and accuracy of the pulse measurement

  • 30 – 160 beats per minute, scale: 1 beat per munite
  • Accuracy: ±2 beats per minute oder 2% of the measured values

The non-invasive

oscillometric measurement


The non-invasive auscultatory and oscillometric measurements are simpler and quicker than invasive measurements, require less expertise, have virtually no complications, are less unpleasant and less painful for the patient. However, non-invasive methods may yield somewhat lower accuracy and small systematic differences in numerical results. Non-invasive measurement methods are more commonly used for routine examinations and monitoring.


The oscillometric method was first demonstrated in 1876 and involves the observation of oscillations in the sphygmomanometer cuff pressure which are caused by the oscillations of blood flow, i.e., the pulse.


The first fully automated oscillomettric blood pressure cuff was made available in 1981. It uses a sphygmomanometer cuff, like the auscultatory method, but with an electronic pressure sensor (transducer) to observe cuff pressure oscillations, electronics to automatically interpret them, and automatic inflation and deflation of the cuff. The pressure sensor should be calibrated periodically to maintain accuracy.


Source: Wikipedia

Warranty

The leagal warranty regulations apply to the OSTAR HK-809 heart spectrum blood pressure monitor with the following limitation/exception:


  • Limioted warranty for the compressor (less than 10.000 opertations),


  • The cuff is a consumable.